Specifications
40
5.2 I/O Specs
Cable and connector specifications and connection examples for the Acquisition Trigger
input and the high-speed outputs are provided in the following sections.
5.2.1 Acquisition Trigger Input
The acquisition trigger input on the sensor is opto-isolated. To trigger from an NPN (pull-
down) type photo-detector or PLC output, connect pin 2 (TRG+) to +24V and connect pin 3
(TRG-) to the output of the detector. When the output turns ON, it pulls TRG- down to 0V,
turning the opto-coupler ON.
To trigger from a PNP (pull-up) photo-detector or PLC output, connect pin 2 (TRG+) to the
output of the detector and connect pin 3 (TRG-) to 0V. When the output turns ON, it pulls
TRG+ up to 24V, turning the opto-coupler ON.
Figure 5-1: Acquisition Trigger Input Schematic
Table 5-6: Acquisition Trigger Input Specifications
Specification Description
Voltage ON 20 to 28V (24V nominal)
OFF 0 to 3V (12V nominal threshold)
Current ON 2.0 to 2.9mA
OFF <150µA
Resistance ~10,000 Ohms
Delay In-Sight 5100, In-Sight 5400C,
In-Sight 5400CS, In-Sight 5400,
In-Sight 5400S, In-Sight 5400R
62µSec maximum latency between leading edge of trigger and start of
acquisition. Input pulse should be minimum of 1 ms wide.
In-Sight 5403, In-Sight 5403S 66µSec maximum latency between leading edge of trigger and start of
acquisition. Input pulse should be minimum of 1 ms wide.
In-Sight 5000, In-Sight 5401 76µSec maximum latency between leading edge of trigger and start of
acquisition. Input pulse should be minimum of 1 ms wide.
NOTE:
When using the sensor with the Breakout cable, the polarity of the input trigger (pins 2 and 3)
is not critical. However, when using the optional Breakout or I/O Expansion Modules, the
polarity of the TRG+ and TRG- terminals should be observed.
Zobrazit stránku 53
1 2 ... 49 50 51 52 53 54 55 56 57 58 59 ... 75 76

Komentáře k této Příručce

Žádné komentáře

Whirlpool AKT 301/IX manuales

Manuales del propietario y guías del usuario para Estufas Whirlpool AKT 301/IX.
Ofrecemos 3 manuales en pdf Whirlpool AKT 301/IX para descargar gratis por tipos de documentos: Manual de usuario


Whirlpool AKT 301 IX Manual de usuario (1 paginas)


Marca: Whirlpool | Categoria: Stoves | Tamaño: 0.37 MB |

 

Tabla de contenidos





Más productos y manuales para Estufas Whirlpool

Modelos Tipo de documento
Ninguno